9.3 Exchanging the battery unit
If the battery unit or parts thereof are defective, do not try to
open and/or repair the battery. The battery unit must always be
exchanged in one piece. To do this, follow the steps outlined in
chapter 5.1, „Installing the battery“.
Always dispose of damaged or defective batteries in
accordance with local regulations.
9.4 Exchanging the battery in the
pewag levo remote radio control unit
If the radio control battery status lights up, the battery is weak
and must be replaced soon. To do this, open the cover of the
pewag levo remote by pressing on the area below the bracket
(1). The cover may now be removed (2) and the battery is
visible. Remove the battery from the holder (3) and replace
it with a new battery (button cell type CR2032, 3V). When you
have finished, gently press down the cover on the casing of the
radio control unit.
9.5 Exchanging the fuse of the
multi- adapter
The multi-adapter comes with
a 10 A micro-fuse (slow) that is
safe and easy to exchange by
the user. Disconnect the multi-
adapter from the mains.
The fuse holder is located on
the side next to the connector
(fig. 13, marked red). Use a
flat-headed screwdriver to turn
the fuse holder by 90° and pull
it out carefully. Exchange the
fuse and put the fuse holder
back into place.
Fig. 12: Exchanging the battery in the pewag levo remote radio control unit
1
2
3
Fig. 13
9. Cleaning, maintenance,
regular inspections
We recommend keeping the original packaging of the
pewag levo clamp LC throughout its entire lifespan in case
of returns!
9.1 Cleaning
In case of heavy soiling, the pewag levo clamp LC should be
cleaned as follows:
• Outer surface of the casing, attachment mechanism and
cam: using a cloth and, where required, a non- aggressive
fat solvent.
• Plastic parts (e.g. battery cover, on/off button): with a dry cloth.
• Battery compartment or inner part of the battery: with a dry cloth.
Do not use high-pressure cleaners, steam blasters or similar
devices for cleaning.
9.2 Maintenance & repair
The pewag levo clamp LC must be checked for visible
damage and/or dirt prior to each use. The following faults may
be rectified by a competent person in accordance with this
manual:
• Cleaning in case of heavy soiling.
• Damaged, missing or illegible safety stickers and markings
(e.g. identification plate).
• Exchanging the battery unit.
• Exchanging the battery in the pewag levo remote control.
With all other faults, the pewag levo clamp LC must be
removed from service and handed for inspection and repair to
pewag or an authorised pewag dealer (also see chapter 9.6
Regular inspections and repairs).
Always use original pewag spare parts!
The pewag levo clamp LC may no longer be used if any of the
following applies:
• Cracked or deformed casing, attachment mechanism or cam.
• Blocked cam during opening or closing.
• Damaged battery cells.
• Missing or illegible identification plate.
• Loose or missing other parts such as covers or screws.
• Heavy soiling or corrosion.
Under no circumstances are users permitted to bend, weld or
otherwise repair parts that are deformed, cracked or broken!
Remove the battery prior to each repair measure to avoid
accidental activation of the cam.
Discard criteria
• Cracked or deformed casing.
• Deformed lifting eye (max. deformation >5 % hole diameter).
• Bending sideways of lifting eye.
• Rounded tips on the cam teeth.
• Grooves in the contact surface.