background image

6

Translation of original operating manual for PLEW pewag winner profilift eta lifting point

February 2018

4.5 Repairs

•  Repairs may only be carried out by the manufacturer or a 

competent person.

• Welding (to repair purposes) and heat treatment are not 

permitted.

• If small defects like notches or score marks are visible 

you can remove them with carefully polishing or filing. 

After repairs, repairs area must be intergradient, without 

a sudden change in cross-section. Due to complete 

elimination of the error may be the cross-section by no 

more than 5 % decreases. 

• Inspections and repairs need to be fully documented and 

remain with the product for the duration of its operating life. 

A documentation reference sheet can be downloaded at 

www.pewag.com.

Each lifting point is stamped with a unique serial number

based on the template “JJ/xxxx“. “JJ” refers to the year 

(e.g. 13 for 2013) and “xxxx” is the unique category number.

5. Storage

Store the lifting point after it has been cleaned, dried and 

protected against corrosion (e.g. lightly oiled). During storage 

or transportation, make sure the product is not exposed to 

corrosive, thermal or mechanical influences.

This information applies to both before and after

welding on the final product.

6. Decommissioning

This lifting point is made of metal and is 100 % recyclable. 

At the end of its service life, the product should be recycled 

as scrap metal.

7. Declaration of conformity

pewag austria GmbH

A-8041 Graz, Gaslaternenweg 4, Phone: +43 (0) 50 50 11-0, Fax: +43 (0) 50 50 11-100
office@pewag.com, 

www.pewag.com

Subject to technical modification and printing errors.

pewag austria GmbH,

 Mariazeller Straße 143, 8605 Kapfenberg

Stefan Duller

General Manager

Translation of original 
declaration of conformity

as defined by EC directive 2006/42/EC, Annex II A

Kapfenberg, 01-07-2016

We,

pewag austria GmbH, A-8605 Kapfenberg, Mariazellerstraße 143a

declare herewith that the product

PLEW pewag winner profilift eta lifting point

complies with all the provisions of the EC machinery directive 2006/42/EC.

Applied harmonized standards in particular:

EN 1677-1: Components for slings-safety – part 1: 
Forged steel components but mechanical values acc. to pewag internal standard

EN ISO 12100: Safety of machinery. General principles for design. 
Risk assessment and risk reduction

Other applied technical standards and specifications:

DGUV GS OA 15-04: Principles of testing and certification of lifting points

Authorized person for the configuration of the declaration documents:

Ranko Ivanic, pewag austria GmbH, A-8605 Kapfenberg, Mariazellerstraße 143a

B

G/00100