6
Translation of original operating manual for PLEW pewag winner profilift eta lifting point
February 2018
4.5 Repairs
• Repairs may only be carried out by the manufacturer or a
competent person.
• Welding (to repair purposes) and heat treatment are not
permitted.
• If small defects like notches or score marks are visible
you can remove them with carefully polishing or filing.
After repairs, repairs area must be intergradient, without
a sudden change in cross-section. Due to complete
elimination of the error may be the cross-section by no
more than 5 % decreases.
• Inspections and repairs need to be fully documented and
remain with the product for the duration of its operating life.
A documentation reference sheet can be downloaded at
www.pewag.com.
Each lifting point is stamped with a unique serial number
based on the template “JJ/xxxx“. “JJ” refers to the year
(e.g. 13 for 2013) and “xxxx” is the unique category number.
5. Storage
Store the lifting point after it has been cleaned, dried and
protected against corrosion (e.g. lightly oiled). During storage
or transportation, make sure the product is not exposed to
corrosive, thermal or mechanical influences.
This information applies to both before and after
welding on the final product.
6. Decommissioning
This lifting point is made of metal and is 100 % recyclable.
At the end of its service life, the product should be recycled
as scrap metal.
7. Declaration of conformity
pewag austria GmbH
A-8041 Graz, Gaslaternenweg 4, Phone: +43 (0) 50 50 11-0, Fax: +43 (0) 50 50 11-100
office@pewag.com,
www.pewag.com
Subject to technical modification and printing errors.
pewag austria GmbH,
Mariazeller Straße 143, 8605 Kapfenberg
Stefan Duller
General Manager
Translation of original
declaration of conformity
as defined by EC directive 2006/42/EC, Annex II A
Kapfenberg, 01-07-2016
We,
pewag austria GmbH, A-8605 Kapfenberg, Mariazellerstraße 143a
declare herewith that the product
PLEW pewag winner profilift eta lifting point
complies with all the provisions of the EC machinery directive 2006/42/EC.
Applied harmonized standards in particular:
EN 1677-1: Components for slings-safety – part 1:
Forged steel components but mechanical values acc. to pewag internal standard
EN ISO 12100: Safety of machinery. General principles for design.
Risk assessment and risk reduction
Other applied technical standards and specifications:
DGUV GS OA 15-04: Principles of testing and certification of lifting points
Authorized person for the configuration of the declaration documents:
Ranko Ivanic, pewag austria GmbH, A-8605 Kapfenberg, Mariazellerstraße 143a
B
G/00100