![background image](http://html1.mh-extra.com/html/pf/origen-esp-esp9000/origen-esp-esp9000_installation-operation-and-maintenance-manual_1534144011.webp)
Parameter List
in
Parking and access control equipment manufactured in the UK
Automatic Sliding Gates
11
Parameter Number
Change to
What this parameter does
P.991
0200
Tells the panel it is connected to a gate
P.990
1
Sets the gate back to default
WARNING!
P.802
0302
Activates Plug in loop Detector
IF YOU HAVE ONE FITTED
P.702
0801
Set Output 2 to release the brake on the motor
p.507
0501
Enables the top photocells
p.506
0501
Enables the bottom photocells
p.450
300
Increases the lag error detection time
p.438
50
Increases the rotation direction error time
p.352
15
Speed for
start
of close
p.350
25
Speed for close
p.312
15
Speed for
start
of open
p.310
25
Speed for open
p.216
1
Prevents the gate re-learning it own parameters.
p.F00
0
Turns off Wireless Safety Edge System
1. Follow the guide on page 10, to enter the menu.
2. Scroll to parameter P.990 change the value to 1 (this will default the panel to factory default)
3. Continue to change the parameters to the values below.
Please note you DO NOT need to use these unless you have a problem!!
!
!! P.216 Must be set to “1" when calibration has finished