Rev.: 2004-001-DE
14
After pressing the green
START
-key a message will remind you of your duty to fix and prepare the
pipes according to the general guidelines:
Is the pipe scraped ?
If you have any doubt about the right preparation, you can break off the procedure by actuating the red
STOP
-key. Confirm the proper preparation by pressing the green
START
-key.
Resistor Error
Now, the welding device begins to measure the fitting resistance. In the case that it is outside the valid
range, the error will be indicated by a bleep and a appropriate message will appear in the display:
1,68< 2,00 < 1,93
Nom. time: 200 s
+PF+ [ d063
Resistor error
Row 1 shows in the middle the measured resistance. At the left and right the borders of the resistance
range given in the barcode is shown.
Row 2 shows the nominal welding time.
Row 3 shows the report number of the faulty process.
Plug the welding terminals out of fitting plugs. Check the connectors of the fitting and welding cable for
dirt or coating. If the fitting causes another resistor error, it maybe defect. Replace it.
If no resistor error occurs, the welding device starts the welding process automatically.
To avoid
danger for your health, do not touch the fitting or cables during the welding process.
The
display shows the actual and nominal welding time:
Act. time: 0099 s
Nom. time: 0200 s
+PF+ [ d063
Row 1 shows the actual welding time, which is counted upwards.
Row 2 shows the nominal welding time.
Row 3 shows the manufacturer, type and diameter.
Row 4 shows possible error messages.
Summary of Contents for Polymatic
Page 2: ...Rev 2004 001 DE 2...
Page 23: ...Rev 2004 001 DE 23 9 Conformity Declaration...
Page 24: ...Rev 2004 001 DE 24...