Rev.: 2004-001-DE
16
You can confirm the correctness of the welding parameters by pressing the green
START
-key. The
following message will remind you of your duty to fix and prepare the pipes according to the general
guidelines:
Is the pipe scraped?
If you have any doubt about the right preparation, you can break off the procedure by actuating the red
STOP
-key.
Confirm the proper preparation by pressing the green
START
-key.
The welding device starts the welding process automatically.
To avoid danger for your health, do
not touch the fitting or cables during the welding process.
The display shows the actual and
nominal welding time:
Act. time: 0099 s
Nom. time: 0200 s
PLAS 40V
Row 1 shows the actual welding time, which is counted upwards.
Row 2 shows the nominal welding time.
Row 3 shows the manufacturer PLAS and 40V to indicate the FUSAMATIC
©
mode
Row 4 shows possible error messages.
The welding process will stop automatically when the actual time reaches the nominal time. This will be
indicated by two bleeps and the following message:
Act. time: 0200 s
Nom. time: 0200 s
PLAS 40V
+OK+
Pull off the welding connectors to go back to the start message.