Rev.: 2004-001-DE
21
8.5 Error messages
Error messages will be indicated by a bleep. A permanent bleep can be interrupted by pressing the red
STOP
-key.
Error
Cause
Reaction
Faulty input.
Move the reading pen with a constant
velocity over the barcode.
Code error
Barcode defect or error of code
structure.
Current high
Output current is more than 15%
higher than the starting current.
Shortcut of fitting coil or welding cable.
Interrupt of the welding current.
Welding is faulty!
Current low
Current drops down about
15-20% for at least 3s.
Welding is faulty!
Device too hot
Temperature of transformer is too
high
Let the device cool down for about 45
min.
Emergency cut-out
Welding was interrupted by pressing
the
STOP
-key.
Welding is faulty!
Frequency error
Input frequency out of working range
(40-70Hz).
Check Generator.
Input voltage high
Input voltage >300V at 230V nom.
Input voltage >150V at 110V nom.
Adjust generator voltage to 240V-260V.
Adjust generator voltage to 120V-130V.
Input voltage low
Input voltage < 190V at 230V nom.
Input voltage < 90V at 110V nom.
Unroll the power supply cable.
Use power supply cable with the right
diameter.
Adjust Generator voltage.
Interturn shortc.
The current rises more than 15%
during the welding. Shortcut of the
fitting coil.
Welding is faulty!
No complete electrical contact with
the fitting.
Check connection to the fitting.
No contact
Fitting coil or welding cable is defect.
Use an other Fitting.
Change welding cable.