Rev.: 2004-001-DE
22
Error
Cause
Reaction
Output volt. error
The output voltage deviates from the
rated voltage.
Check the generator.
Revolutions fluctuate or power too
weak.
Power failure
Last welding was interrupted by a
break of the power supply.
Last welding is faulty! Prepare pipe
again and use a new Fitting!
Fitting resistance is out of the valid
working range.
Clean the contacts.
Use an other fitting.
Resistor error
Fitting resistance outside the valid
tolerance range given by the barcode.
Clean the contacts
Use an other fitting.
Service
The recommended service interval of
200 working hours is exceeded.
The device has to be checked by an
authorized service point.
The device is still usable, but the
manufacturer does not accept any
liability for the device until it is checked
up.
System error
Danger! Selftest found an error in the
system.
Disconnect power supply immediately.
Do not connect the device to the power
supply any more. Send it to the next
service point.
Temp. Meas. error
Temperature measurement is faulty.
Plug in the removable welding cable.
Switch device off and on.
Welding cable or sensor defect.
Temperature error
Surrounding temperature out of
working range (-10-+50°C).