Adjustment
13
Fig. 13 - 08
13
.05.07
Feed lifting height
Requirement
At maximum stitch length setting and in o.T. Needle bar (adjustment hole
1
), the feed dog
should stand in the middle of the throat plate cutout and lie against the setting gauge
over its entire length.
Set the maximum stitch length and position the needle bar appropriately.
Place the adjustment gauge (Order No.
61-111 642-19
) on the needle plate so that its
recess is centered above the feed slots (arrow pointing in feed direction) and lower the
presser foot.
Loosen screws
1
and
2
.
By turning cranks
3
and
4
and the eccentric sleeve 5 adjust the feed dog according to the
requirement.
1
2
1
3
4
3
5
4
Summary of Contents for 3806-12/22