Adjustment
18
Speed
control unit
A 1 X5: 28 0
Output
Output number
Connector
Contact
number
Output status
The output can be switched on
for 200 ms by pressing key D+
3.
01.03
Test block 2 – outputs
SWG -2 D
Pedal
position
3.
01.04
Test block 3 – speed control unit
3.
01.05
Test block 4 – actual value transmitters
●
The functions allocated to the inputs displayed can be found in
Part 3 Parameter list and
connection plan.
●
It is possible to move to all 16 switch levels by operating the pedal.
●
If all the displays from
-2, -1, 0, 1, 1D
to
12D
appear, the speed control unit is in order.
IWG 136
Actual value
transmitter
Increments
●
The actual value transmitter can be checked by turning the balance wheel.
●
If the increments from 0 – 255 appear on the display, the actual value transmitter is in order.