16
Controls
●
The machine as a keyboard with
4
keys to activate different functions.
●
When the keys
1
–
4
are operated on the standard version, the functions listed below are
carried out.
Key
1
:
Reverse sewing or intermediate backtacks during the seam.
(For drive system P45 PD2-L = standard)
For drive system AB 321, the value
16
is set under parameter
244
(= standard).
Key
2
:
Needle position change
This button can have the
following functions
assigned depending on the drive
system implemented and by way of changes to the parameter values:
P45 PD2-L
AB 321
Parameter
Function
Parameter
Function
446
1 = needle raised without trimming
2 = needle position change
3 = single stitch
4 = not allocated
5 = tack inversion
6 = tack suppression
242
01 = Change needle position (standard)
02 = needle up without trimming
03 = Single stitch
17 = inversion
96 = Backtack suppression
(all autom. backtack deactivated)
97 = Single stitch reverse
98 = Not used
Fig. 7 - 04
1
2
3
4
7
.04
Keyboard on machine head
(only on the PFAFF 2235 PLUS)
Summary of Contents for PowerLine 2235