Controls
Key
4
:
EMERGENCY KEY.
( needle is raised without trimming, the thread clamp is opened, the thread
tension is released, the presser foot raised and the motor start inhibitor activated)
Deactivation the motor safety lock
For drive system P45 PD2-L - click the button '
Scroll
'.
For drive system AB 321 - click the button '
E
' (under parameter
247
, the value
24
is
set = standard)
The method for setting parameters is described in the settings manual, and
may only be carried out by certifi ed professionals!
Key
3
:
This button can have the
following functions
assigned depending on the drive
system implemented and by way of changes to the parameter values:
P45 PD2-L
AB 321
Parameter
Function
Parameter
Function
748
1 = threading aid + needle raised
without trimming
2 = needle position change
3 = single stitch
4 = not allocated
5 = tack inversion
6 = tack suppression
249
91 = Needle up without trimming
(= standard)
01 = Change needle posoition
03 = Single stitch
17 = inversion
96 = Backtack suppression
(all autom. backtack deactivated)
97 = Single stitch reverse
98 = Not used