32
Care and maintenance
9
.04
Checking/regulating the air pressure
●
Check the air pressure on gauge
1
every
time before operation.
●
Gauge
1
must show a pressure of
6
bar.
●
Regulate this pressure if required.
●
To do so, pull knob
2
up and turn it accor-
dingly.
Fig. 9 - 03
2
1
9
.05
Emptying/cleaning the water bowl of the air fi lter/regulator
Switch off the machine.
Disconnect the air hose at the
air fi lter/regulating unit.
Emptying the water bowl
●
Water bowl
1
empties itself automatically
when the air hose is disconnected from
the air fi lter/regulator.
Cleaning the fi lter
●
Unscrew water bowl
1
and take out fi l-
ter
2
.
●
Clean the fi lter with compressed air
or with isopropyl-alcohol, part number
95
-
665735
-
91
.
●
Screw in fi lter
2
and screw on water
bowl
1
.
Fig. 9 - 04
1
2
Summary of Contents for PowerLine 2235
Page 35: ...Note ...