Operating instructions CWB-ATEX
120799 61 616 07 300 0
05/2021
Page 6 / 14
30046-005k
en
5 Technical Data
Explosion Protection
Gas and Dust
EPS 20 ATEX 1 222 X
II 2G Ex db eb IIC T* Gb
II 2D Ex tb IIIC T* °C Db
* see ambient conditions for temperature class
X
The device is suitable for a low degree of mechani-
cal hazard. Observe the warning notice in the chap-
ter
7.2 Mounting / dismounting, operating position
Certifications and certificates
Certificates
Ship approval
ATEX
EPS 20 ATEX 1 222 X
DNV-GL
TAA00002GU
Electrical Data
CWB-ATEX
Rated voltage range
Rated current
12 V...48 V DC (0 Hz)
24 V .. 42 V AC 50/60 Hz
0.
3 … 0.5 A
60 V...80 V DC
42 V...48 V AC 50/60 Hz
0.13
– 0.11 A
0.3 A
110 V...127 V AC 50/60 Hz
0.11 A
230 V AC
50/60 Hz
0.08 A
CWB-ATEX-MX
24 V DC ± 20 %
0.4 A
Back-up fuse
4 AT
(Fuse slow-blow or automatic circuit breaker C charac-
teristic)
Protection class
I
(internal and external PE connection terminal accord-
ing to IEC/EN 60598)
Optical Data
Flash energy
5 Joules
Flash frequency
1 Hz
Duty Cycle
100%
Service Life
8 x 10
6
flashes
Ambient Conditions
Ambient temperature
T
amb
Gas
Dust
-40 °C .. +40 °C
T6
T85 °C
-40 °C .. +50 °C
T5
T100 °C