Safety data sheets
You can obtain the safety data sheets for lubricants from Pfeiffer Vacuum on request, or
from the
Pfeiffer Vacuum Download Center
.
The lubricant type is specified on the rating plate
1. Please refer to rating plate of the vacuum pump for type and quantity of intended lubricant.
2. Only use the lubricant which was applied during initial installation.
– Contact Pfeiffer Vacuum if you want to use another type of lubricant.
Prerequisites
● Vacuum pump switched off and cooled
● Vacuum pump vented
Required consumables
● Lubricant
Required tools
● Ring spanner,
WAF 8
● Ring spanner,
WAF 22
● Open-end wrench,
WAF 38
Required aids
● Cleaning cloth
● Collection receptacle
● Funnel (optional)
7.4.1 Draining lubricant on the motor side
1
3
2
Fig. 13:
Draining lubricant on the motor side
1 Magnetic sealing plugs
3
Drain screw
2 Collection receptacle
Procedure
1. Place a collection receptacle beneath the drain hole on the motor side.
2. Unscrew the drain screw.
3. Unscrew the magnetic sealing plug.
4. Fully drain the lubricant.
5. Clean the magnetic sealing plug.
6. Screw in the magnetic sealing plug and drain screw.
Maintenance
36/52