Checking the installation of the thermometer
► Check the installation dimension "X" and tighten the clamping screw if necessary.
– X =
112 mm
5.6.2 Arrange a signal evaluation for the thermometer
A restart following "zero potential" without resetting the interlock of the ignition system is
not permissible.
Device cate-
gory
EPL
Result of the ignition
hazard evaluation for
the existing device
Ex “b” ignition protec-
tion system necessary
Ignition system
3
Gc
No effective ignition
sources are to be ex-
pected during normal
operation
The signal must be evaluated without the
use of an ignition protection system
2
Gb
No effective ignition
sources are to be ex-
pected during normal
operation
An individual system in
order to avoid ignition
sources where expected
malfunctions are expect-
ed
b1
In accordance with DIN EN ISO 80079-37, the b1 ignition protection system complies with safety re-
quirement level SIL1 and the IEC 61508 series of standards, and a "performance level" PL c in ac-
cordance with the ISO 13849 series of standards
Tbl. 10:
EPL (Equipment protection level)
Procedure
► Set up the ignition protection system on the operator side in accordance with the requirements for
the device category or EPL.
► Observe the necessary ignition protection system type
Regular check
► Check the thermometer at regular intervals.
– Compare with other process temperatures.
► You can obtain information on calibration directly from
.
5.7 Connect to mains power supply
DANGER
Danger to life from electric shock
Touching exposed and voltage-bearing elements causes an electric shock. Improper connection of
the mains supply leads to the risk of touchable live housing parts. There is a risk to life.
► Before the installation, check that the connection leads are voltage-free.
► Make sure that electrical installations are only carried out by qualified electricians.
► Provide adequate grounding for the device.
► After connection work, carry out an earthed conductor check.
WARNING
Risk of fatal injury due to electric shock on account of incorrect installation
The device's power supply uses life-threatening voltages. Unsafe or improper installation can lead to
life-threatening situations from electric shocks obtained from working with or on the unit.
► Ensure safe integration into an emergency off safety circuit.
► Do not carry out your own conversions or modifications on the unit.
Installation