Installation
13
Install the connection cable between the electronic drive unit and the turbopump.
Secure mounting brackets, snap in plugs and close screw connections.
5.3
Earthing
Fig. 6:
Installing the earthing connection
5.4
Connecting to the mains power supply
Fig. 5:
Connecting the turbopump to the electronic drive unit TCP 1200
5
Connection "pump1. output"
6
Control connection "pump2. output"
13.1 Connection "pump"
13.2 Control connection "pump"
13.3 Connection cable TCP - turbopump
5
13.1
13.3
13.2
6
WARNING
Danger of electric shock
In case of defect, the parts connected to the mains supply can be energized.
Connect the pump with PE according to local regulations, before mains connection.
Connect appropriate earthing cable on the customer side.
Pay attention to the minimum cross-section of the mains connection.
M4
WARNING
Danger of unsafe electrical installation
Safe operation after installation is the responsibility of the operator.
Do not independently modify or change the pump and electrical equipment.
Make sure that the system is integrated in an emergency off safety circuit.
Consult Pfeiffer Vacuum for special requirements.