14
Installation
Fig. 7:
Pin assignment of the mains connection plug
Order the mains cable separately (see "accessories").
Insert the mains cable into the mains connection
AC in
.
Lock the mains cable with the mounting bracket.
WARNING
Danger due to lack of power disconnection device
Pump and electronic drive unit are not equipped with a power disconnection device. In-
stallation of a user-supplied power disconnection device in accordance with SEMI-S2.
Fit a circuit breaker with an interruption rating of min. 10,000 A.
WARNING
Danger of electric shock
In case of defect, the parts connected to the mains supply are under voltage.
Always keep the mains connection freely accessible so you can disconnect it at any
time.
1
Phase L
2
Neutral conductor
3
n.c.
PE
Protective earth
1
2
3
PE