Putting the machine into service
Transport the assemblies as closely as possible to the object to be
processed (refer to Transport for the assembly).
Lock the castor before putting the machine into service.
¾
Connect the water intake to a ¾" hose. Open the supply line to vent and
clean the hose line. Close the supply line again.
¾
Connect the water hose to the water inlet (1).
¾
Close the drainage valves (2) on the water manifold.
WARNING!
When working with water from the tank, the suction inlet must be fitted with
a water filter (item no. 00 00 69 06) (deaerate water pump).
The machine may only be connected to a worksite switchgear assembly
with 32 A fuse protection and a 30 mA earth leakage circuit breaker that
conforms to regulations. The connection cable must correspond to version
H07 RN-F 5 x 4.0 mm². The earthling socket is available for connecting all
230 V consumers (such as portable lamps etc.) and the water pump for
5-pin connections only.
WARNING!
The protective grille may not be removed while preparing or operating the
machine. For the safety of the operator, the protective grille is equipped with
a magnetic switch which switches off the machine when removing the grille.
Before the control box is connected to the power supply, the following must
be observed:
Turn off the main reversing switch (1) (“0” position, lockable).
Turn the star wheel switch (2) to “0”.
Pull the blind plug (3).
Connect the mixer pump motor.
1
2
3
1
2