PFT G 54 E
Operating Instructions
09/2006
Knauf PFT GmbH & Co.KG
24
Then open the water valve until the sponge ball comes out of the end of the
hose. For different hose diameters, the hoses should be cleaned separately
with the appropriate sponge balls.
Repeat this procedure if the hoses are very dirty.
Clean the spraying gun separately under running water.
Close the water intake valve.
Depressurise the water hose by opening and then carefully disconnecting
the water valve on the side.
Now disconnect the power supply.
WARNING!
The main switch must be switched off or the power supply disconnected
before removing the hopper cleaning flap.
Empty the material hopper if the machine is probably not going to be used
for several days.
To do so, the wing nut on the outside of the base of the container under the
star wheel motor should be opened.