PFT G 54 E
Operating Instructions
09/2006
Knauf PFT GmbH & Co.KG
26
Release the tie rod screws, remove the pump, push the rotor out of the
stator and clean it thoroughly. Clean the pressure flange or agitator
(ROTOMIX or ROTOQUIRL). Clean the mixing area and the mixing shaft
with water and a spatula. Then assemble the entire pump and prepare it for
operation.
Measures to be taken in the event of a water supply failure
Use the suction inlet (item number 00 00 69 06) and high pressure pump to supply the machine
with clean water from a container.
Measures to be taken if there is a risk of frost
After cleaning the machine:
Interrupt the water supply.
Take out the mixing shaft.
Close the water supply.
Open the water outlet valve (1) and relieve the water pressure
in the hose.
Disconnect the water hose (2) and empty it.
Open the outlet tap on the water manifold.
Remove the air hose from the spraying gun and connect it to
the water inlet (water pump) and the outlet of the air manifold
(control box).
Switch on the main switch.
1
2