PFT G 54 E
Operating Instructions
09/2006
Knauf PFT GmbH & Co.KG
54
Check list for annual inspection by specialist (master copy)
This inspection must be carried out once a year by a specialist in accordance with ZH1/575. The
machine and control box are awarded an inspection label as verification of this inspection. The
inspection protocol is to be presented on demand.
Date of
inspection:
Inspector: Signed: Machine
number:
Component Inspection
feature
OK
Rework/
Replace
Material hopper
Check all welded seams
Material hopper
Destroyed by corrosion or deformation?
Mixing area
Check wall of tube for wear
(minimum wall thickness of 1.5 mm)
Mixing shaft
Check wedge profile in mixing area for wear
Mixing shaft
Check pump coupling for wear
Protection grille
Is protective grille still even?
Frame
Check all welded seams
Frame
Check whether all screwed joints are fitted tightly
Frame
Check for distortions. Stability must be ensured
Rollers
Do rollers turn easily?
Water flow meter Is the inspection glass still clearly transparent and
sealed?
Solenoid valve
Functional check
Pressure reducing
valve
Functional check (check 1.9 bar setting)
Control box
Visual inspection for defects
Control box
Functional check
Control box
Are all labels in a good readable condition?
Control box
High voltage check with 1000 V
Control box
Functional check of all safety switches
Control box
Functional check of all control lamps
Control box
Check whether all cable connections are fitted
tightly
Type plate
Available and legible
Operating
instructions
Available
Mortar pressure
gauge
Functional check