Mixing pump RITMO L / RITMO M Overview - Operation
Description of assemblies
2016-02-17
17
8.3 Overview air compressor DT4.8 230 V
Fig. 13: Air compressor
1. Capacitor.
2. Air for spraying gun.
3. Safety valve up to 1.8 bar.
4. Air filter.
5. Non-return valve.
6. Power supply 230 V.
7. Pressure switch compressor (switches the
compressor ON/OFF).
8. Connection pressure control.
9. Pressure switch air (switches the machine
ON/OFF).
8.4 Overview water fitting RITMO L / RITMO M
1
2
3
4
5
6
7
Fig. 14: Water fitting
1. Water flow meter.
2. Pressure reducer.
3. Pressure monitor Water pressure.
4. Connection of water from mains.
5. Water to mixing tube.
6. Stopcock / water removal.
7. Connection Water removal Cleaning mortar
pressure hose.
8. Drain tap Frost protection.
9. Needle valve Water quantity.
10. Pressure gauge Inlet pressure Water.
11. Solenoid valve.
1
2
3
4
5
6
7
9
8
11
10
9
8