Mixing pump RITMO L / RITMO M Overview - Operation
Intended use air compressor
22
2016-02-17
14.2 Safety systems air compressor
WARNING!
Danger of death due to non-functioning safety
equipment!
Safety equipment ensures highest level of safety in
operation. Even if work processes become a little
more complicated due to safety equipment, they
must never be decommissioned. The safety is
guaranteed only with intact safety equipment.
Therefore:
Before starting work, check if the safety
equipment is functioning properly and has been
correctly installed.
Use safety equipment at all times.
Do not obstruct access to safety systems such
as emergency stop buttons, pull cords etc.
14.3 General positioning of the air compressor
The air compressor complies with the national and international
safety regulations and can therefore also be used in damp rooms
and/or outdoors. Areas with clean and dry air should be preferred.
Ensure that the device can freely suck in the air. This applies in
particular if an installation is intended.
The air compressor should only be set up in such a way that no
dangerous additives, such as solvents, vapours, dusts or other
harmful substances can be sucked in. The device should be
positioned only in rooms where the hazard of a potentially
explosive atmosphere is not given.
14.4 Hot surface of the air compressor
General information
WARNING!
Danger of injury due to hot surface!
During operation the compressor can reach a
surface temperature of up to 100 °C. Therefore it
has to be ensured that the device does not get into
contact with bare body parts during use as well as
for some time after use in relation to the heating
temperature.