Mixing pump RITMO L / RITMO M Overview - Operation
Switching on RITMO L
34
2016-02-17
26 Switching on RITMO L
26.1 Putting RITMO L into operation
Fig. 41: Switching on
1. Turn main switch (1) to position "I".
2. Switch the selector switch (2) “Operation with water” towards
the left to the position with water.
26.2 Presetting the water flow rate.
Fig. 42: Water sampling valve
Fig. 43: Presetting
1. Close all water drain taps at the water fittings block.
2. Open the water tap for water feed.
3. Open stopcock (1) until the water appears without bubbles.
Close the stopcock (1) again.
4. Press the water supply button (2)
(Fig. 43)
as long as no air
bubbles are to be seen in the water flow meter (3) any longer.
5. Adjust the expected amount of water at the needle valve (4).
Evident with the ball in the inspection glass of the water flow
meter (5).
NOTE!
The specifications of the material manufacturer
are to be observed here.
NOTE!
Any interruption of the spray operation results in a
slight irregularity in the consistency of the
material. This irregularity normalises by itself as
soon as the machine has been working for a short
while.
Therefore it is important not to change the water
quantity for each irregularity. Wait until the
consistency of the material has set again.
6. Connect the water hose (6)
(Fig. 42)
to the water inlet (7) of the
rubber mixing section.
1
2
1
6
7
3
5
4
2