Mixing pump RITMO L / RITMO M Overview - Operation
Apply mortar
2016-02-17
41
Fig. 60: Switching on vibrating unit
2. Turn the selector switch (2) clockwise.
3. The vibrating unit runs after the set intervals, 3 seconds pause
– 3 seconds run time.
35 Apply mortar
DANGER!
Risk of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and
face.
– Never look into the spraying device.
– Always wear protective goggles.
– Always position yourself in such a way that you
are not hit by the mortar being discharged.
NOTE!
The possible conveying distance depends mainly
on the flowability of the mortar. Heavy, sharp-
edged mortar has poor flow characteristics. Runny
materials have good flow characteristics.
If 15 bar or 20 bar operating pressure are
exceeded, the hose length must be reduced.
35.1 Open the air tap at the spraying gun
Fig. 61: Switching on
Fig. 62: Opening the air tap
1. Turn the selector switch direction of rotation of the pump motor
(1) clockwise.
2. Aim the spray gun at the wall to be plastered.
3. Ensure that nobody is in the discharge area of the spraying
gun.
4. Open the air tap (2) at the spraying gun.
5. The machine will start-up automatically via the pressure switch-
off and the mortar emerges at the spraying gun.
NOTE!
The correct mortar consistency is reached, if the
material mixes on the surface to be sprayed (we
recommend application on wall surfaces from top
to bottom). If the water quantity is too little even
mixing and spraying is no longer guaranteed;
blockages may form inside the hose and high wear
of the pump parts will become an issue.
2
1
2