Mixing pump RITMO L / RITMO M Overview - Operation
Work on troubleshooting
2016-02-17
47
40.4 Switching on RITMO M again after power failure
2
1
3
Fig. 77: Undervoltage trigger
NOTE!
The RITMO M is equipped with an undervoltage trigger.
In case of a power cut, the system has to be started as
follows.
1. Turn the selector switch (1) to the “Null” position towards the left.(centre
position).
2. Close the air tap at the spraying gun.
3. Press the green push button (2) Operation “ON”.
4. Turn poti (3) for motor speed / material quantity to position 7 (adjust as
required).
5. Turn the selector switch (1) clockwise.
6. The RITMO M starts again as soon as the air tap at the spray gun is
opened again.
NOTE!
In case of a longer power cut, the RITMO M and the
material hoses have to be cleaned immediately.
41 Work on troubleshooting
41.1 Reaction in the event of faults
The following strictly applies:
1. In the event of faults presenting immediate danger to persons
or property, activate the emergency OFF function immediately.
2. Determine cause for fault.
3. If the rectification of faults requires works in the danger zone,
switch off the system and secure against restarting.
4. Inform the manager on site immediately about the fault.
5. Depending on the type of fault commission authorised skilled
personnel or rectify the fault yourself.
NOTE!
The following fault table gives information on who
is authorised to rectify the fault.