Mixing pump RITMO L / RITMO M Overview - Operation
Removal of clogging in hoses
54
2016-02-17
43.3 Switch machine back on after blockage has been cleared RITMO L
2
1
3
1
Fig. 84: Switching on RITMO L
1. Turn the selector switch (1) to the “Null” position towards the
left.(centre position).
2. Close the air tap at the spraying gun.
3. Turn main switch (2) to position “I”.
4. Turn poti (3) for motor speed / material quantity to position 7
(adjust as required).
5. Turn the selector switch (1) clockwise.
6. The RITMO L starts again as soon as the air tap at the spray gun
is opened again.
43.4 Switch machine back on after blockage has been cleared RITMO M
1
3
Fig. 85: Switching on RITMO M
1. Turn the selector switch (1) to the “Null” position towards the
left.(centre position).
2. Close the air tap at the spraying gun.
3. Press the green push button (2) Operation “ON”.
4. Turn poti (3) for motor speed / material quantity to position 7
(adjust as required).
5. Turn the selector switch (1) clockwise.
6. The RITMO M starts again as soon as the air tap at the spray
gun is opened again.
2