Mixing pump RITMO L / RITMO M Overview - Operation
End of work / Cleaning
58
2016-02-17
44.7 Cleaning the mixing tube
Fig. 91: Open motor tilt flange
NOTE!
Material no longer be present in the material
container and in the mixing tube.
1. Remove the 10-pole plug (1).
2. Remove the nut (2) at the protective grille and tilt backwards
with the motor.
NOTE!
During cleaning work and during the transport of the
motor, connect the socket housing with the
protective cover (3) (protection from moisture).
Fig. 92: Remove the agitator.
3. Remove the mixing shaft (4) and clean it.
4. Cleaning the mixing zone with a spatula.
44.8 Insert the mixing tube cleaner
Fig. 93: Insert the mixing tube cleaner
1. Insert the cleaning shaft and mixing tube cleaner (1) into the
mixing tube.
NOTE!
Insert the mixing tube cleaner (1) with the scrapers
pointing downward.
Fig. 94: Cleaner shaft position
NOTE!
When inserting the cleaner shaft ensure
that the cleaner shaft (2) engages
correctly in the drive dog in the head of
the rotor (3) and when closing the motor
flange (4).
2
3
1
4
1
3
2
4