Mixing pump RITMO L / RITMO M Overview - Operation
End of work / Cleaning
2016-02-17
59
44.9 Cleaning mixing tube RITMO L
Fig. 95: Cleaning RITMO L
1. Close the motor flange (1).
2. Firmly tighten the nut (2) at the protective grille.
3. Insert the 10-pole plug (3).
4. Turn main switch (4) to position “I”.
5. Turn poti (5) for motor speed / material quantity to position 3
(adjust as required).
6. Turn the selector switch (6) directions of rotation of the pump
motor clockwise (machine starts).
7. Let the machine run for about 5-10 seconds until the mixing tube
has been cleaned.
8. Turn the selector switch (6) to the “Null” position (centre position).
9. Remove the 10-pole plug (3).
10. Remove the nut (2) at the protective grille and tilt backwards with
the motor.
11. Remove the mixing tube cleaner with the cleaner shaft from the
material container.
44.10 Cleaning mixing tube RITMO M
3
2
Fig. 96: Cleaning RITMO M
1. Close motor flange
(Fig.95)
.
2. Firmly tighten the nut at the protective grille
(Fig.95)
.
3. Insert the 10-pole plug
(Fig.95)
.
4. Press the green push button (1) operation “ON”.
5. Turn poti (2) for motor speed / material quantity to position 3
(adjust as required).
6. Turn the selector switch (3) directions of rotation of the pump
motor clockwise (machine starts).
7. Let the machine run for about 5-10 seconds until the mixing tube
has been cleaned.
8. Turn the selector switch (3) to the “Null” position.(centre position).
9. Remove the 10-pole plug
(Fig.95)
.
10. Remove the nut at the protective grille and tilt backwards with the
motor.
(Fig.95)
11. Remove the mixing tube cleaner with the cleaner shaft from the
material container
1
2
4
6
3
1
5