Mixing pump RITMO L / RITMO M Overview - Operation
Changing the pump / cleaning the pump
2016-02-17
61
45 Changing the pump / cleaning the pump
45.1 Place the machine on the back side
Fig. 101: Move the machine
1. Secure the machine against switching on by removing the
connection cable.
NOTE!
For changing the pump slightly / cleaning the
pump, place the RITMO on the back side.
Fig. 102: Remove pump unit
2. Loosen the nuts (1).
3. Remove the pump unit (2) with mortar pressure gauge and
clean it.
4. Insert new rotor and stator or the cleaned pump unit and tighten
nuts.
NOTE!
Assembled pump (rotor in stator) are stored for a
few days only as rotor and stator can get
connected inseparably in case of prolonged
storage.
46 Switching off RITMO L
Fig. 103: Switching off RITMO L
1. Turn the selector switch (1) to the “Null” position (centre
position).
2. Turn the main switch (2) to position “0”.
47 Switching off RITMO M
Fig. 104: Switching off RITMO M
1. Turn the selector switch (1) to the “Null” position (centre
position).
2. Press the red push button (2) operation “OFF”.
1
1
2
2
1
2
1