Mixing pump RITMO L / RITMO M Overview - Operation
Maintenance work
2016-02-17
67
50.6 Air compressor slider control / air filter cleaning
Fig. 117:
Air filter
1. Clean the prefilter weekly.
2. Loosen the tension springs and remove the filter insert.
3. Blow through the prefilter with compressed air from inside to outside (see
Figure below).
4. Replace clogged, oily, greasy or damaged filter cartridges at any cost.
Article number for filter cartridge D050x58: 00 08 75 47
5. The compressor works without oil and should not suck oil mist.
6. The ambient temperature may not exceed 45°C.
7. It is essential to store the compressor dry and to avoid the condensate
through water vapour.
8. It is prohibited to use the machine in explosive atmosphere.
High temperatures are generated on the compressor due to air
compression.
Protection from contact with hot surfaces
or protect the traffic area
or attach warning signs.
If a prefilter has not been mounted yet, clean the filter of the compressor
weekly.
1. With the prefilter, clean the filter integrated in the compressor only every four
weeks. Loosen the screws at the side cover.
2. Take the filter out, and blow through with compressed air from
inside to outside (do not wash out).
3. Replace clogged, oily, greasy or damaged filter cartridges at any
cost.
Article number for filter cartridge: 00 07 77 66