HOT WIRE CUTTING TOOL Overview - Operation - Spare parts lists
Preparation
Page 38
29.07.2013
22.5 Power connection
Fig. 25: Power connection
Before commissioning, check whether the current type and voltage
comply with the specifications on the name plate.
Connect PFT CUTMASTER only to a 230V AC network.
DANGER!
Danger of death from electric current!
The connection line has to be fused properly:
– Connect the machine only to a site main cabinet
with RCCB (30 mA).
22.6 Main cutting bow and supporting angle
Fig. 26: Cutting bow
Move the cutting bow (1) from the idle position and let it click into
place at the 90° position.
NOTE!
Ensure that the knurled screws are loosened above
and below on swivelling the main bow, otherwise the
ball slide rails while unnecessarily be burdened.
Wheel round both the supporting angles (2 + 3) in the desired
position, loosen the cylinder grips (4) here and then tighten it again.
22.7 Storage screw for support angle
Fig. 27: Storage screw
The angle required for a project can be set with the storage screw
(1). In the meantime, desired further steps can be carried out, in
order to return to the default angle.
2
3
1
4
1