HOT WIRE CUTTING TOOL Overview - Operation - Spare parts lists
Fuse protection
Page 42
29.07.2013
The angle of the front cutting wire 16 can be freely adjusted in the
provided groove by the wire bonding (with wire hook) movable
lengthwise into the front cutter 11. For this, loosen the knurled
screw, shift the wire onto the desired position and tighten the
knurled screw by hand. Tension the front cutting wire 16 after
changing the angle every time by loosening, shifting and tightening
the two-wing nut fitted inside centrally on the front cutter.
In order to recommission the main cutting wire 15, proceed as
described earlier in the reverse sequence. Make sure to lock the
front cutter 11 when open using the clamping lever 17, in order to
prevent wheeling around of the main cutting wire 15 in the work
area.
24 Fuse protection
24.1 Transformer
Fig. 34: Transformer
The transformer is doubly protected:
••••
Thermal switch-off in case of overheating.
••••
Via fuse, fitted in the white fuse holder (1).
••••
Replacement fuses (2).
Article number for the micro fuse: 00 10 34 03
NOTE!
In case of overheating, PFT CUTMASTER can be
used further after 30 minutes of cooling-down time.
1
2