PFT ZP 3 L MULTIMIX Overview – Operation – Spare Parts Lists
Preparation of the machine
24
2016-07-04
Fig. 22: Set-up
Install the machine on stable and even ground and secure it
against accidental movements.
If necessary, place an underlay under the support foot (1) to
ensure the machine cannot subside during operation.
Place the machine where it cannot be hit by any falling
objects.
The controls must be freely accessible.
22.2 Mains voltage connection
1
2
Fig. 23: Electrical connection
Only connect the machine (1) to AC current with 400 V.
DANGER!
Danger of death due to electric current!
The electrical connection must be fused
correctly:
Only connect the machine to a power source
with an approved FI circuit breaker (30 mA)
RCD (residual current device) of type “A”.
Disconnect the control circuit by removing the dummy plug (2) on the
control box.
WARNING!
Before starting operation, either remove the dummy
plug or press the remote control.
Fill the ZP 3 L material hopper with approx. 5 l of
water to ensure the screw pump does not run dry
when starting up.
WARNING!
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The motor must be operated only with the control
cabinet of the machine.
NOTE!
Never allow the pump to run dry, since this will
shorten its service life.
1