PFT ZP 3 L MULTIMIX Overview – Operation – Spare Parts Lists
Switching off MULTIMIX
2016-07-04
31
30 Switching off MULTIMIX
Fig. 45: Switching off MULTIMIX
1. Switch off the machine at the main reversing switch.
31 Switching on the ZP 3 L and putting it into service
31.1 Processing material
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes and
face.
Therefore:
Never look into the spraying gun.
Always wear protective goggles.
Always position the machine so that you cannot
be hit should mortar escape.
NOTE!
The maximum pumping distance depends primarily
on the flow characteristics of the mortar. Heavy,
coarse-grained mortar does not flow well. Fluid
materials have good flow characteristics.
Uniform spraying cannot be ensured if the amount
of water is insufficient. This can clog the hoses and
the pumping components are then subjected to
greater wear.
If operating pressure exceeds 20 bar, either the
length of the mortar hose must be reduced or
thicker mortar hoses need to be used.