Switching on the ZP 3 L and putting it into service
32
2016-07-04
31.2 Switching on the ZP 3 L briefly
2
1
Fig. 46: Switching on
1. Press the green push button (1) to switch the control voltage
“ON”.
2. Allow the ZP 3 L to run until all the wallpaper paste has
emerged from the end of the mortar hose.
3. Collect the wallpaper paste with a suitable container and
dispose of it according to regulations.
4. Switch off the machine at the red push button (2) so the control
voltage is “OFF”.
NOTE!
Never allow the pump to run dry, since this will
shorten its service life considerably.
31.3 Connecting a spraying gun
1
3
2
Fig. 47: Spraying gun
1. Connect the mortar hose to the spraying gun (1).
2. Connect the air hose to the spraying gun (2).
3. Make sure that the air valve (3) on the spraying gun is
closed.
4. The ZP 3 L can be switched on or off at the air valve (3)
using the pressure control.
31.4 Connecting the air hose for the spraying gun
2
1
Fig. 48:
Connecting the air hose
1. Connect the air hose (1) from the spraying gun to the EWO
coupling (2).