PFT ZP 3 L MULTIMIX Overview – Operation – Spare Parts Lists
Switching off in an emergency
2016-07-04
35
32.2 Switching off the air compressor
1
Fig. 57:
Switching off the air compressor
1. Switch the compressor off using the red push button (1).
33 Switching off in an emergency
Switching off in an emergency
Machine movements and the energy supply must be disabled
as quickly as possible in dangerous situations.
Fig. 58: Switching off
Proceed as follows in the event of an emergency:
1. Switch off the main reversing switch immediately.
2. Secure the main reversing switch against being activated
again using a padlock.
3. Inform supervisors at the site.
4. If necessary,
call emergency services.
5. Remove persons from the danger zone and carry out first-
aid measures.
6. Ensure emergency vehicles have unobstructed access.
After the emergency response
7. If the seriousness of the emergency warrants this, inform
the responsible authorities.
8. Assign specialist personnel to begin rectifying the fault.
WARNING!
Danger of death due to premature
restarting!
All persons in the danger zone are at extreme
risk when the machine is switched back on.
Ensure that the danger zone is clear before
switching the machine back on.
9. Check the equipment before switching it back on and
ensure that all safety devices are in place and functioning
properly.