SWING M delivery pump / Part 2 Overview, operation and service
Operation
5.3.4.2 Connecting the mortar hose
2
1
Figure 21: Connecting the mortar hose
1. Connect the mortar hose (1) to the mortar pressure gauge (2).
NOTE
Ensure clean and correct connection and tightness of
the couplings! Dirty couplings and rubber seals are not
watertight, and water might leak under pressure inevitably
leading to blockages.
2. Lay mortar hoses with a radius large enough so that the hoses do
not kink.
3. Carefully secure risers so that they do not tear away from their own
weight.
NOTE
Fill the material hopper with approx. one litre of wallpaper
paste or slurry so that the pump does not run dry when
starting up
3
4
5
7
6
Figure 22: Switching on
4. Close the control circuit by inserting the dummy plug (3).
5. Turn the pump motor selector switch (4) to "right" position
6. Turn potentiometer for motor speed / material volume (5) to posi-
tion 4.
7. Switch the machine on by pressing the green pushbutton (6)
control voltage "ON".
8. Allow the machine to run until all the wallpaper paste has emerged
from the end of the mortar hose.
9. Collect the wallpaper paste in suitable container and dispose of as
per regulations.
10.Switch off the machine by pressing the red pushbutton (7) control
voltage "OFF".
NOTE
Never let the pump run dry as this reduces the service life
of the pump.