SWING M delivery pump / Part 2 Overview, operation and service
Operation
5.8
Switching off the air compressor
1
Figure 37: Switching off the air
compressor
1. Switch off the air compressor at the on/off switch (1).
2. Open air tap on the spray gun so that the residual pressure can
escape.
WARNING
Danger of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and face.
Beware of residual pressure.
5.9
Switching off the machine
2
1
Figure 38: Switching off the machine
1. Turn the pump motor selector switch (1) to the "0" position.
2. Switch off the machine by pressing the red pushbutton (2) control
voltage "OFF".
5.10
Action in case of power failure
1
Figure 39: Interrupting the control
circuit
Interrupting the control circuit
1. Close the air tap on spray gun.
2. Pull out the dummy plug (1) to interrupt the control circuit.
3. Switch off air compressor.
4. Have the power supply connection checked by an expert.
page 31 / 52