Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Description
4.4.1
Mixing tube with material hopper
Figure 12: Material hopper assembly
Mixing tube with material hopper, pump unit and pump motor.
The pump motor with tilt flange can be removed from the mixing
tube for transport purposes.
4.4.2
Chassis with compressor and control box
Figure 13: Chassis assembly
Chassis with water manifold, control box and compressor.
4.4.3
Control box
1
2
3
4
5
7
6
8
9
10
11
[1]
Main reversing switch is also emergency-stop switch
[2]
Selector switch, compressor "ON / OFF"
[3]
Pushbutton for control voltage "ON/ OFF"
[4]
Selector switch for operation with water (as mixing pump),
without water (only as pump)
[5]
Yellow control lamp, change the direction of rotation
[6]
Potentiometer for motor speed / material volume
[7]
Red control lamp, motor protection switch activated
[8]
Yellow control lamp, operation 230V
[9]
Pump motor selector switch
[10] Water supply button
[11] Sight glass for frequency converter
14
13
12
Figure 14: Assembly unit control box
[12] Main power connection 400V or with adapter main power
connection 230V
[13] Safety socket for air compressor connection
[14] CEE mounted socket for connection of delivery hood
page 23 / 76