Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Description
4.5
Connections of water and air
4
5
3
2
1
Figure 17: Connections
[1]
Water sampling valve
[2]
Connection air to spray gun
[3]
Connection water supply from mains
[4]
Mortar hose connection on mortar pressure gauge
[5]
Water connection from water manifold to mixing tube
4.6
Operating modes
Figure 18: Air compressor selector
switch
Air compressor selector switch
The air compressor can be operated in two different operating modes:
Switch position "0":
The air compressor is switched off.
→ For pumping screed
Switch position "1":
The air compressor is switched on. As soon as the compressor has
built up pressure in the pipeline system, it switches off using the
pressure switch-off.
→ For spraying plasters with compressed air
Figure 19: Pump motor selector switch
Pump motor selector switch
The pump motor has three operating modes:
Switch position "0":
The machine is switched off.
Switch position "right" (latching):
The machine starts up when the power supply is correctly and
completely switched on.
Switch position "left" (spring return):
The pump motor goes into reverse, thereby relieving the pump and
locking other functions.
page 25 / 76