Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
5.3.4
Checking the strainer screen
2
1
Figure 35: Checking the strainer
screen
1. Unscrew the brass screen cup (1) with outlet tap from the pressure
reducer.
2. Check whether the strainer screen (2) in the pressure reducer is
clean.
Screen for pressure reducer:
Item no. 20156000
3. Screw on brass screen cup (1) again.
4. Close all water outlet taps.
5.3.5
Connecting the water supply
1
2
Figure 36: Connecting the water
1. Check whether the water inlet screen in the water inlet (1) is clean.
2. Clean and vent the water hose from the water supply.
3. Connect the water hose to the water inlet (1).
4. Remove the water hose (2) from the mixing tube.
5. Open the water tap of the water supply line.
NOTE
Use only clean water free of solids. The minimum pres-
sure is 2.5 bar when the machine is running.
Observe the Drinking Water Protection Ordinance in
Part 1
NOTE
Never let the pump run dry as this reduces the service life
of the pump.
page 35 / 76