Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
6
5
4
3
Figure 73: Blowing the water manifold
dry
2. Turn the main reversing switch (3) to position "I".
3. Press the green pushbutton (4) control voltage "ON".
4. Turn the air compressor selector switch (5) to the "1" position.
5. Press and hold the water supply button (6) for approx. 10 seconds.
6. The water is now blown out of the manifold with compressed air.
7. Open all outlet taps and blow out with compressed air again.
8. Turn the air compressor selector switch (5) to the "0" position.
9. Turn the main reversing switch (3) to position "0".
NOTE
Make sure that the water fully flows out of the water mani-
fold.
5.13
Ending work / cleaning the machine
5.13.1
Cleaning
Clean the machine daily at the end of work and in case of
extended breaks.
NOTE
Water can enter sensitive machine parts!
Before cleaning the machine cover all openings in
which no water must enter for safety and functional
reasons (e.g.: electric motors and control cabinets).
Remover the covers completely after cleaning.
5.13.2
Secure against restarting
WARNING
Danger to life from unauthorised restarting!
When working with the machine there is the risk that the
energy supply is switched on without authorisation. This
poses a danger to life for the persons in danger area.
Before starting work, switch off all electrical power
supplies and secure them against being switched back
on again.
If the protective covers are removed for cleaning
purposes, it is essential that they be properly reat-
tached when work is finished.
page 52 / 76