Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Description
Figure 20: Water selector switch
Water selector switch
The RITMO can be used for two application areas:
Switch position "right" (latching):
The machine is operated without water.
→ Can be used as a feed pump
Switch position "left" (latching):
The machine is operated with water.
→ Use as mixing pump
4.7
Voltage 230V/400V changing
1
Figure 21: Change voltage
Voltage change-over switch (1) 230V, 1 phase or 400V, 3 phase is
located in the control cabinet
Delivery state position of voltage selector to 400V
Change voltage:
1. Turn the main switch to position "0".
2. Open the control cabinet door.
3. Switch the voltage switch (1) to 230V or 400V.
4. Close the control cabinet door.
5. Turn the main reversing switch to position "I".
6. Press the green pushbutton control voltage "ON".
4.8
Pressure booster pump
The PFT pressure booster pump is used predominantly as a high-
pressure pump for intermediate connection at the mortar mixer when
the water pressure is too low. It can also be used as a primer pump for
drawing liquids from containers, for emptying small tanks and ponds,
for pumping water out of cellars and for irrigation.
The water supply is automatically ensured from a water tank by the
PFT pressure booster pump for the constant water supply to the PFT
machine engineering.
A flow pressure of at least 2.5 bar with the machine in operation on
the construction side is guaranteed by means of suction from the
water reservoir.
page 26 / 76