Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
5.3.3.2 Connecting the power supply 400V
Figure 32: Connecting the power
supply
1. Connect machine to three-phase network 400V.
DANGER
Danger to life from electric current!
The electrical connection must be fused correctly:
Only connect the machine to a power source with
an approved RCD (residual current device) of type A
(30 mA).
The machine can be switched to 230V, 1 phase and oper-
ated, although it is connected to a 400V, 3 phase supply.
Benefits:
The motor speed can be controlled via the poten-
tiometer.
Disadvantage:
As the machine is controlled via the frequency
converter, the pump motor no longer reaches its full
capacity (maximum 4 kW).
5.3.3.3 Connecting the individual connectors
1
2
Figure 33: Power connections
3
Figure 34: Connecting the motor
connecting cable
WARNING
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The respective drive (motors) must be operated only
with the control box of the machine.
1. Connect the power supply for the delivery hood (1).
2. Connect the power supply for the air compressor (2).
3. Connect motor connecting cable (3) to pump motor.
page 34 / 76