Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
5.11
Action in case of power failure
Figure 66: Turn the main reversing
switch to the "0" position
Turn the main reversing switch to the "0" position
1. Close the air tap on spray gun.
2. Turn the main reversing switch to position "0".
3. Switch off air compressor.
4. Have the power supply connection checked by an expert.
5.11.1
Discharging mortar pressure
2
1
Figure 67: Check and relieve the
mortar pressure
WARNING
Overpressure on the machine!
When opening machine parts they can open in an uncon-
trolled manner and injure the operator.
Only open the mortar hoses if the mortar pressure
gauge (1) indicates the pressure has fallen to "0 bar".
WARNING
Danger of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and face.
Never look into the spray gun.
Always wear protective goggles.
Always position yourself in such a way that you are not
hit by the mortar being discharged.
1. Open air tap on the spray gun.
2. Check the mortar pressure gauge (1) if the mortar pressure has
fallen to "0 bar". If necessary, discharge any mortar pressure by
unscrewing the nuts (2) slightly. When doing so, cover the work
area with tear-proof film.
3. Tighten nuts (2) again.
page 49 / 76