Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
2
1
Figure 82: Closing the motor tilt flange
5
4
3
6
Figure 83: Cleaning the mixing tube
Cleaning the mixing tube
CAUTION
Danger of crushing at the motor tilt flange!
There is a danger of crushing injuries when closing the
motor tilt flange.
Never reach into the closing range of the motor tilt
flange.
1. Close motor tilt flange with gear motor (1).
2. Close quick fastener (2).
3. Insert 10-pole connector plug.
4. Turn the main reversing switch (3) to position "I".
5. Press the green pushbutton (4) control voltage "ON".
6. Turn the pump motor selector switch (5) to "right" position.
The machine starts.
7. Allow the machine to run for approx. 5 - 10 seconds until the mixing
tube is cleaned.
8. Turn the pump motor selector switch (5) to the "0" position.
The machine stops.
9. Press the red pushbutton (6) control voltage "OFF".
10.Pull out 10-pole connector plug.
11.Open the quick closure (2) and tilt the motor.
12.Remove the mixing tube cleaner with cleaner shaft from the mixing
tube and place it in the holding device.
5.13.5.2 Cleaning the rubber mixing zone
3
2
1
Figure 84: Removing the pump unit
1. Remove the water hose (1) from the mixing tube.
2. Loosen the nuts (2) on both sides.
3. Remove pump unit (3) with pressure flange and mortar pressure
gauge and clean.
page 56 / 76