Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Operation
5.14.6.3 Switching on the machine after removing a blockage
1
2
3
4
Figure 91: Switching on the machine
again
1. Turn the main reversing switch (1) to position "I".
2. Press the green pushbutton (2) control voltage "ON".
3. Turn the pump motor selector switch (3) to "right" position.
4. Let the machine run for a short while without mortar hoses.
5. As soon as material flows out of the pressure flange, switch the
pump motor selector switch (3) to the "0" position.
6. Apply wallpaper paste to the cleaned mortar hoses and connect to
the machine and spray gun.
7. Turn the air compressor selector switch (4) to the "1" position.
8. Turn the pump motor selector switch (3) to "right" position.
9. The machine starts again as soon as the air tap on the spray gun is
re-opened.
page 64 / 76