Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
Maintenance
6.4.2
Air filter compressor
3
1
2
Figure 93: Cleaning the filter
Implementation by a service technician
1. Unscrew the covers (1 & 2).
2. Remove the filter frame (3).
3. Blow through the filter frame from the inside to the outside or tap it.
4. Replace the filter in case of heavy contamination.
5. Insert filter frame and screw on covers (1 & 2).
6.4.3
Strainer screen in the water inlet
Figure 94: Strainer screen in the water
inlet
Implementation by operator.
1. Remove the strainer screen from the Geka coupling.
2. Clean the strainer screen.
3. Replace the screen if dirt is severe.
4. Reinsert strainer screen.
Screen for Geka coupling:
Item no. 20152000
6.4.4
Strainer screen in pressure reducer
2
1
Figure 95: Strainer screen
Implementation by a service technician
1. Remove the closure cap (1) from the pressure reducer.
2. Take out the strainer screen (2) and clean (monthly).
3. Replace the strainer screen if dirt is severe.
4. Insert strainer screen and screw on the closure cap.
Screen for pressure reducer:
Item no. 20156000
page 68 / 76