Mixing pump RITMO XL FC-230/400V / Part 2 Overview, operation and service
General information
1.7
Quality Control sticker
Figure 2: Quality Control sticker
The following details can be found on the Quality Control sticker:
CE confirmed as per EU directives
Serial no / serial number
Controller / signature
Date of control
1.8
Intended use
1.8.1
Purpose of fitting block
The fitting block has been designed and constructed only for the
intended use described below.
NOTE
Application range!
Primary use for water and neutral, non-adhesive liquids.
Also suitable for air and neutral non-flammable gases.
Maximum operating pressure (initial pressure) 16 bar.
After-pressure infinitely adjustable from 1.5 to 6 bar.
Smallest possible initial pressure 2.5 bar.
Minimum pressure gradient (initial/after-pressure) 1
bar.
Maximum media and ambient temperature 75 °C.
Assembly position as desired, preferable vertical.
1.8.2
Purpose of solenoid valve
NOTE
Application range!
Solenoid valves for liquid and gaseous media, aggressive
or neutral, can be used in various temperature and pres-
sure ranges
Type 6213 is a 2/2 way solenoid valve with straight
passage, normally closed, with a permanently coupled
membrane system. It switches from 0 bar and is universal
in use for liquids. A minimum differential pressure of 0.5
bar is necessary for complete opening.
page 8 / 76